Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose
Breath-Dx: A Time Series Classification Benchmark for Disease Screening with eNose
Ivan Poddiakov, Ivan Kruzhilov, Galina Zubkova, Svetlana Erofeeva, Andrey Savchenko, Pavel Blinov
2026-11-18▲ 32arXiv 2611.15348v1Hugging FaceCode
AI-generated from the full paper (deepseek-flash). It may contain mistakes; check the original.
TL;DR
Breath-Dx is a public benchmark built on the S-OH dataset of 1,234 patients' 17-channel eNose breath time series, evaluating 10 classifiers under temporal (drift-aware) splits, where all methods lose 0.05-0.12 AUC versus random splits and no single method dominates.
Problem
Electronic nose breath analysis promises non-invasive disease screening, but the field lacks systematic benchmarks comparing machine learning methods under realistic conditions. Existing studies use small, private datasets (often under 100 samples) with inconsistent protocols, so results are non-comparable. Sensor drift, a known failure mode, is rarely quantified, and random cross-validation is commonly used despite mixing temporally close samples. The paper also notes the absence of a large-scale, multi-pathology, multi-site public clinical eNose dataset with drift-aware splits.
Method
The authors release the Scent of Health (S-OH) dataset: 1,234 patients across nine ICD-10 diagnostic groups, each with a 17-channel multivariate time series of T=358 time steps (895 seconds at 0.4 Hz), collected over 13 weeks at two clinical sites. Each disease is framed as one-vs-rest binary classification with a fixed temporal test set and 16 random training splits, reporting mean and standard deviation of ROC AUC with 15% of training data used for validation and early stopping. Ten methods from four families are compared: feature-based tabular learners (CatBoost, XGBoost, HistGradientBoost, RandomForest over Stats_5, LogFit_2, LogFit_4 and polynomial features), convolution-based (CNN, ResNet18 on image-like polynomial feature matrices), graph-based (Graphormer on an 8-node complete graph with 9-dimensional node and 3-dimensional edge features), and time series models (LSTM, InceptionTime, TS2Vec). Temporal splits reserve disease-specific weeks for testing with no patient leakage, and drift is deliberately left uncorrected, with each series scaled individually. Demographic analyses compare age-only, gender-only and age+gender CatBoost baselines and gender- and age-stratified subgroup performance, and a CatBoost model is trained to predict measurement day from raw sensor data to quantify drift.
Results
- All methods degrade under temporal validation compared with random cross-validation, with the average AUC drop across diseases and methods being 0.05-0.12. §VI-B
- Peak performance is reached on lung cancer by InceptionTime and on COPD by Graphormer, while diabetes and tuberculosis remain near chance across all methods. §VI-A
- By average AUC across the nine conditions, LSTM ranks highest, followed by Graphormer and ResNet18, while Graphormer shows high variance and LSTM ranks top-3 for 5 of 9 conditions. §VI-A
- Age alone rivals or exceeds sensor-based models for lung cancer and tuberculosis, whereas for liver disease and gastritis demographic-only models perform poorly while sensor-based models exceed AUC 0.65. §VI-C
- Subgroup analysis shows hepatitis classification is substantially better in women than men, and lung cancer AUC is higher in the older cohort than the overall model. §VI-C
- A CatBoost model trained on raw sensor data predicts the measurement day (1 to 71) with a median absolute error of 2-3 days, confirming a strong temporal signal in the recordings, and the simple logistic regression baseline remains competitive (e.g. K29 AUC 0.718). §V-G
Limitations
- The paper states that although the dataset includes patients from two clinical sites, both used the same eNose device, so cross-device and cross-batch validation are still needed (§VII-E).
- The authors state they did not apply drift correction techniques; the benchmark only establishes baseline performance for future drift-robust methods (§VII-E).
- The paper notes that temporal splits approximate but cannot fully replace prospective validation on new patient cohorts (§VII-E).
- The benchmark is left open on multi-disease modeling: the paper frames exploiting correlations among conditions as future work rather than evaluating it (§VII-E).
Key points
- S-OH is the largest public clinical eNose collection to date: 1,234 patients, nine diagnostic groups, 17-channel multivariate time series of about 15 minutes (895 seconds). §I
- Temporal splits allocate all of a patient's samples to either train or test, use disjoint weeks, and pick different temporal segments per disease, so classifiers must generalize across time. §III-B
- The device uses a multi-electrode chip with 17 co-planar electrode pairs, ZnO-based functional materials, a 0.76 cm3 gas-tight chamber, 300 plus or minus 5 degrees Celsius operation and 0.4 Hz sampling. §IV-B
- Feature-based methods use 8 of the 17 channels chosen a priori for stability; feature sets are Stats_5, LogFit_2, LogFit_4 and polynomial features after smoothing and min-max normalization. §V-B
- Stats_5 features consistently outperform the kinetic LogFit_2 and LogFit_4 feature sets across most ensemble models. §VI-A
- The simple Logistic Regression on concatenated raw signals is competitive on several diseases, and some advanced methods fail to consistently outperform it. §VII-A
- The authors recommend abandoning random cross-validation for eNose studies and treating temporal validation as the minimum standard. §VII-B
- Method choice is framed as a trade-off: LSTM for cross-disease consistency, Graphormer or InceptionTime for peak performance on a specific target, CatBoost with Stats_5 for low cost and interpretability. §VII-C